Vanguard – CT-8000 S3 – Digital Circuit Breaker Analyzer

198
1290
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
Part Number(s)

9103-UC [CT-8000 S3 with 3 Contact Channels]
9104-UC [CT-8000 S3 with 6 Contact Channels]
9103-SC [CT-8000 S3 Shipping Case]
9103-DG [CT-8000 S3 Dual Ground Option]
9103-BT [CT-8000 S3 Bluetooth Option]
9103-OT [CT-8000 S3 Online Timing Option]

  • Fully analyze circuit breaker's performance by measuring main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes
  • Perform dynamic contact resistance test
  • USB computer interface
  • USB Flash drive interface (Flash drive not included)
  • Store up to 200 test records and 100 test plans internally
  • Initiate Breaker Operation
  • Built-in 4.5" wide Thermal Printer
  • Rugged "QWERTY" style membrane keypad
  • Optional "On-line" Timing Mode
  • Optional dual ground testing mode
  • Optional Bluetooth wireless computer interface

The CT-8000 S3 is Vanguard's fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available with 3 (part number 9103-UC) or 6 contact timing channels (part number 9104-UC). The CT-8000 S3 can fully analyze a circuit breaker's performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Also, an outstanding feature of the CT-8000 S3 is the ability to perform dynamic resistance tests on circuit breaker contacts.

       

CT-8000 S3 – Technical Specifications

TYPE Portable circuit-breaker analyzer
PHYSICAL SPECIFICATIONS 16”W x 11”H x 14”D (40.6 cm x 29.9 cm x 35.6 cm); Weight: 22 lbs (9.98 kg)
INPUT POWER 100-240Vac, 10A, 50/60Hz
DRY-CONTACT INPUTS 3 channels (9103-UC) or 6 channels (9104-UC). Channel can detect the main contact and resistor contact time.
TIMING WINDOWS 1 second, 10 seconds, or 20 seconds
TIMING RESOLUTIONS ±50 micro-seconds @ 1 sec. duration,
±500 micro-seconds @ 10 sec. duration,
±1.0 milli-seconds @ 20 sec. duration
TIMING ACCURACY 0.05% of reading ±0.05 ms @ 1 second duration
DRY-CONTACT CHANNEL PROTECTION All contact inputs are grounded until test. Input channels are also protected against static discharge.
DRY-CONTACT DETECTION RANGE Closed: Less than 20 Ohm. Opened: greater than 5000 ohm
INSERTION RESISTOR DETECTION RANGE 50 – 5,000 ohms
TRIGGER INPUT VOLTAGE Open/Close trigger voltage: 24 V – 300V DC or peak AC
VOLTAGE SENSING INPUT RANGE V1: analog input; 0 – 250 V DC or peak AC; sensitivity ±1 V; record and print voltage level
V2 and V3: voltage presence/absence detector input; 24 – 255 V DC or peak AC; record and print 3 timing events
BREAKER OPERATIONS Initiate Open, Close, Open-Close, Close-Open, Open-Close-Open
BREAKER INITIATE CAPACITY 30A, 250 Vac/dc max
INITIATE CURRENT READING RANGE one, non-contact, Hall-effect sensor, 0 – 20 amp range, dc to 5 Khz AC
DIGITAL TRAVEL TRANSDUCER INPUTS 3 digital travel transducer channels; linear range: 0.0 – 60.0 in (±0.01 in)
rotary range: 0 – 360 degrees (±0.36 degrees)
RESISTOR TYPE TRANSDUCER INPUTS 3 channels, 200 ohm – 10K ohms
CONTACT TRAVEL POINT DIFFERENCE measures “slow-close” contact-point distances; results can be printed
DYNAMIC/STATIC RESISTANCE RANGE 0.1 – 1,999 micro-ohms; accuracy: ±2% of reading, ±5 micro-ohms
RESISTANCE TEST CURRENT 200 amperes max
DISPLAY back-lit LCD screen (128 x 240 pixels); viewable in bright sunlight and low light
PRINTER built-in 4.5” wide thermal printer that can print both graphic contact travel waveforms and tabulated test results
INTERNAL TEST RECORD STORAGE Store upt to 200 test records and 100 test plans
EXTERNAL TEST RECORD STORAGE USB Flash drive interface for external storage of test records and test plans
COMPUTER INTERFACES One USB port, optional Bluetooth wireless interface
PC SOFTWARE Windows® based Breaker Analysis software included with purchase price
CABLES furnished with full set of test leads
OPTIONS transportation cases (available for the CT-8000 S3 and travel transducers), on-line timing mode, dual ground testing mode,
bluetooth interface
SAFETY designed to meet UL 6101A-1 and CAN/CSA C22.2 No 1010.1-92 standards
ENVIRONMENT Operating: -10°C to +50°C (+15°F to +122°F);
Storage: -30°C to +70°C (-22°F to +158°F)
HUMIDITY 90% RH @ 40°C (104°F) non-condensing
ALTITUDE 2,000 m (6,562 ft) to full safety specifi cations
WARRANTY one year on parts and labor
Specifications are valid at nominal voltage and ambient temperature of +25˚C (+77˚F).
OPTIONAL TESTING FEATURES
ON-LINE TIMING MODE
ON-LINE CURRENT SENSOR three non-contact AC current sensors, range 0-100 amperes
ON-LINE DC CURRENT SENSOR one non-contact DC current sensor, range 0-20 amperes
DUAL GROUND TIMING MODE
DUAL GROUND CLAMP-ON PROBES 3 non-contact clamp-on probes

Field Pictures

CT-7000 S3/CT-8000 S3 Dual Ground Probes

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | Vanguard – CT-8000 S3 – Digital Circuit Breaker Analyzer .

Comments are closed.