Chandler Engineering-Friction Flow Loop System (Model:6500)

184
1014
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

The Model 6500 Friction Flow Loop fully automated system includes hardware and software to measure the friction pressure of fluids. It determines the associated affects friction reducers have on fluids over a wide range of pressures and flow rate conditions and through different pipe diameters.

This Model circulates fluid through two test sections of various diameters in order to generate differential pressure versus flow rate data. This data helps to determine the effectiveness and longevity of various friction reducing agents added to the test fluids. 

The system incorporates a low shear, progressive cavity pump for injection of base fluids with the flow rate controlled by a Coriolis flow meter. Differential pressure transducers are provided on each tubing diameter for multiple data readings per test. Fluid can be injected into the flow stream via an optional metering pump or added directly into a 15 gallon reservoir mixing tank. 

The software is designed to be easy to use and powerful enough to calculate and collect all required data during the test cycle. The software allows the operator total control over flow rate, test time, temperature (optional) of each individual test. All data and test parameters are stored in a test-specific .CSV file for analysis.

Features

•  Open or Closed Loop Architecture 
•  Easy to Set-Up, Operate, Clean, Maintain and Calibrate 
    – Flush-and-Fill automation for easy system cleanup 
•  Wall or Floor Mountable 
•   ½” and ¾” O.D., 25’ length tubing sections (10’ test sections) 
•  Coriolis Mass Flow Meter 
    – Accurate measurement and feedback of flow rate 
•  Over Pressure Relief Valves 
    – Safety Control – Prevents operation above the designed pressures 
•  Progressive Cavity Style Pump 
    – Provides very low shear to fluids during injection 
•  Real Time Display of Reynolds Number, Flow Rate, Temperature, Differential Pressure


Maximum Pressure:  150 PSI (250 PSI Optional) 
Flow Rate Range:  2 – 15 Gallons / Minute 
Fluid Temperature Range:  60 – 90°F (40°F with Optional Chiller) 
Differential Pressure Range (1):  0 – 30 PSI 
Differential Pressure Range (2):  0 – 100 PSI 
Differential Pressure Accuracy:  0.1% of Full Range

Utilities: 
Power Requirements:  
230V 40A Single Phase 
Dimensions (w x d x h):  30’ x 4’ x 6’ 
Compressed Air:  80-120 psi 

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | Chandler Engineering-Friction Flow Loop System (Model:6500).

Comments are closed.