Minimal Training – Easy to Use
The large liquid-crystal display (LCD) has been incorporated with easy to follow prompts, large fonts, and graphics to help reduce the time needed to get your results. The description on the instruments' soft keypad quickly guides you through specific programs.
The large liquid-crystal display (LCD) has been incorporated with easy to follow prompts, large fonts, and graphics to help reduce the time needed to get your results. The description on the instruments' soft keypad quickly guides you through specific programs.
Mighty Performance with Quantitative Methods
Everything from simple concentration measurements up to sophisticated quantitative calibration curves. Some of the standard functions include:
- Factor method for input of simple constants
- One point calibration curve with one standard sample and a point through the origin.
- Multi-point calibration curve of the application requiring various standards. 1st, 2nd, and 3rd order polynomial filling for calibration come standard.
- Two or three wavelength quantitative analysis for measuring turbid samples or for measuring the effects of another distinguishable component.
Maximum Wavelength Scanning
The UVmini comes standard with a Spectrum mode that allows for full spectral data acquisition over the wavelength range of 190nm to 1100nm. Upon completion of the spectral scan, the peaks and valleys can be marked within a few seconds. The standard peak pick function allows for clear and accurate detection of the most sensitive wavelengths.
Mega Data Archiving Capabilities
Methods, results and raw data can be saved on either the standalone instrument, optional dedicated IC Data cards, or within a directory of an IBM-Compatible PC with the help of the optional NEW UV DATA MANAGER software. This provides unlimited storage and expanded capabilities in archiving methods and management of essential results.
Multiple Print Utilities
The UVmini provides flexible print options with the use of either a thermal screen copy printer or a variety of different PC printers. The screen copy printer enables instant printing of tabulated data, as well as copied information directly from the screen. The PC printers can be utilized for the same functions and for finer print resolution of spectral data.
Mini Effort to Customize
With over 35 different types of attachments including multicell positioners, sippers, temperature control devices, the UVmini can provide all the tools necessary to fit your specific application. The IC program cards quickly expand the functionality of the instrument. By simply inserting the appropriate IC card into the slot on the front panel, dedicated applications such as DNA/Protein analysis can now be performed.
Hardware Specifications UVmini-1240
Item | UVmini-1240 |
---|---|
Spectrum bandwidth | 5 nm |
Wavelength range | 190.0 to 1100.0 nm |
Display wavelength | 0.1 nm step |
Selectable wavelength | 0.1 nm step (1nm step in spectrum mode) |
Wavelength accuracy | ± 1.0 nm |
Wavelength repeatability | ± 0.3 nm |
Scan speed | Wavelength change: approximately 3800 nm/min Scan: approximately 24 to 1400 nm/min |
Light source change | Selectable from following 3 types; – Auto change with wavelength Selectable wavelength 295 nm to 364 nm: 1 nm interval Recommended wavelength: 340 nm – Halogen lamp (WI) only – Deuterium (D2) lamp only |
Stray light | less than 0.05% (220.0 nm NaI, 340.0 nm NaNO2 & UV39) |
Measurement method | Single beam measurement |
Photometric range | Absorbance: −0.3 to 3.0 Abs Transmittance: 0.0 to 200% |
Recording range | Absorbance: −3.99 to 3.99 Abs Transmittance: −399 to 399% |
Photometric accuracy | ± 0.005 Abs (at 1.0 Abs) ± 0.003 Abs (at 0.5 Abs) |
Photometric repeatability | ± 0.002 Abs (at 1.0 Abs) |
Drift | less than ± 0.001 Abs/h (after 2 hr warm-up) |
Baseline flatness | ± 0.010 Abs (after 1 hr warm-up, at 1100 to 200 nm) |
Noise | less than 0.002 Abs, Peak to Peak less than 0.0005 Abs, RMS |
Light source | Auto correction with the computer memory 20W Halogen lamp (long-life 2000 hours) Deuterium lamp (socket type) Auto adjustment for maximum sensitivity |
Monochromator | Incorporates aberration-correcting concave blazed holographic grating |
Detector | Silicon photodiode |
Sample compartment | Interior dimensions W110.0 × D230.0 × H105.0 mm (partial depth: 155.0 mm) 2 screw port for option accessory installation |
Display | 6 inch LCD (320 X 240 dot) with CFD lighting with contrast adjustment |
Power supply | 100 to 120 V 50/60 Hz 160 VA 220 to 240 V 50/60 Hz 160 VA |
Dimensions | W416 X D379 X H274 mm |
Weight | 11 kg |
Ambient temperature | 15 to 35°C |
Ambient humidity | 45 to 80%, less than 70% if over 30°C |