Shimadzu- Energy-Saving Gas Chromatograph (Model:GC-2025)

184
960
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

Shimadzu’s new-generation GC-2025 capillary gas chromatograph minimizes environmental impact by reducing power and carrier gas consumption while retaining the performance capabilities required for capillary analysis.

The GC-2025 incorporates a digital flow controller that controls both the carrier and detector gases and a newly designed energy-saving column oven that features small volume and less heating loss, realizing a dramatic improvement in operation costs.

The compact GC-2025 is the gas chromatograph for environmentally friendly, high value performance

Eco-Friendly

Comparison of Power Consumption

Comparison of Power Consumption Per Analysis Cycle

The eco-friendly GC-2025 significantly cuts electric power costs compared to previous models to reduce the burden on the environment.
Heat losses are significantly reduced through high-performance insulation and a smaller oven size to reduce the heating requirements. In addition, it incorporates an energy-saving heater to further cut power costs.
Power consumption is reduced by 30% for programmed temperature analysis in comparison to other GC models.
(The actual power consumption depends on the ambient temperature during analysis.)

Compact, All-in-One Design

In recent years, there has been an increasing demand for instruments with a smaller installation footprint to more effectively utilize laboratory space. The GC-2025 meets this requirement while incorporating all the functions required for normal capillary analysis.

Comparison of GC (Top View)

Comparison of GC (Top View)

Units for Normal Analysis Crowded into a Compact Space

The split/splitless injection unit (SPL), flame ionization detector (FID), and electronic flow controllers (AFC/APC) are installed as standard.

Compact Design Accepts Commercial Capillary Columns Despite the compact instrument design, the small-capacity oven accommodates the shape of commercially available capillary columns (column depth 9 cm max.).

Excellent Basic Performance

Incorporating design elements from the high-performance GC-2010 Plus capillary gas chromatograph, the GC-2025 achieves energy savings while offering the highest performance demanded for capillary analysis, delivering highly accurate analysis results and enhanced productivity.

High-Sensitivity Trace Analysis

The FID minimum detectable limit of 2 pgC/s offers high sensitivity for trace analysis.

Electronic Flow Controllers Achieve Excellent Operability and Reproducibility

The GC-2025 adopts the same well-proven electronic flow controllers (AFC/APC) for carrier gas and detector gas control that are used in the GC-2010 Plus. They offer highly accurate flow control to achieve excellent reproducibility.

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | Shimadzu- Energy-Saving Gas Chromatograph (Model:GC-2025).

Comments are closed.