ICO61 is a programmable digital panel meter 96 x 24 mm for electrical measurements in 10,000 points. It is possible to change the configuration of measurement type, range, limits and scaling. The configuration of these parameters is protected against any inopportune modifications.
- Panel meter size: 96 mm x 24 mm
- IP40 protected
- Programmation through 3 front keys
- Measurement hold function
- Registration of maximum and minimum value of a measurement burst
- Measurement, display and scaling of:
- DC and AC voltage up to 400 V
- DC current up to 2,000 A with an external shunt
- AC current up to 200 A + Current transformer, with secondary current of 1 A or 5 A
- Frequency up to 5,000 Hz
- 2 programmable limits with relays output
- 9 different power supplies available
Electrical measurement indicator
Type | Range | Resolution | Accuracy (1 year) (23°C ± 1°C) |
Input impedance |
DC voltage | 500 mV 5 V 50 V 400 V |
100 μV 1 mV 10 mV 100 mV |
0.1% + 100 μV 0.1% + 1 mV 0.1% + 10 mV 0.1% + 0.1 V |
> 100 MΩ 1.1 MΩ 1 MΩ 1 MΩ |
AC voltage | 500 mV 5 V 50 V 400 V |
100 μV 1 mV 10 mV 100 mV |
0.7% + 1 mV 0.5% + 6 mV 0.5% + 60 mV 0.5% + 0.6 V |
1 MΩ 1 MΩ 1 MΩ 1 MΩ |
DC current | 4-20 mA or 0-50 mA 1 A (2) 5 A (2) |
10 µA 1 mA 1 mA |
0.2% + 10 µA | shunt 10 W included external shunt 100 mV external shunt 100 mV |
AC current | 1 A (2) 5 A (2) |
1 mA 1 mA |
external shunt 100 mV external shunt 100 mV |
|
Frequency (3) | 5 to 500 Hz 5 to 5000 Hz |
0.1 Hz 1 Hz |
0.1% + 0.1 Hz 0.1% + 1 Hz |
10 MΩ 10 MΩ |
Temperature coefficient: ≤ 10% accuracy/°C
Continuous mode: -40 to 100 % range.
Alternate mode: 4 to 100 % range from 25 to 500 Hz without D.C component (possible measurements up to 10 kHz on some ranges with less precision).
(1) Extended measurement range: -40 to +110% range.
(2) With external shunts
(3) Two levels of input voltage: 50 mV~ to 50 V~ and 5 V~ to 250 V~.
Frequency:
– 70 V peak on low entry level (50 mV to 50 V)
– 570 V peak on entry high level (5 V to 250 V)
Further features
Ranging | Automatic |
Measurement hold | Short-circuit on the rear panel |
Scaling | The value is to be entered using keyboard, while the value of measurement corresponding can be is introduced of the same way, is measured by the instrument. This possibility is very interesting for error corrections on temperature ranges. |
Sampling rate | 2.5 samples / s |
Comments are closed.