Yokogawa- PC-BASED DATA ACQUISITION UNIT(Model: MX100)

859
3760
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
  • MX100 Style S3 New!
    • 30-ch input module
    • Windows Vista compatible
    • Alarm levels increased from 2 to 4
  • Multi-Channel Capability, High Isolation Voltage
  • Multi-Interval Measurement
  • Flexible System Configuration
  • Versatile PC-Based Software Options
  • Easy Software Setup
  • No Re-Wiring between Measurements
  • All-in-one "Quick Start Packages" with 10, 20, or 30 Channels

Features

High-Speed Multi-Channel Capability

The table below provides reference information on the maximum number of measurable channels in relevant measurement intervals (when using Yokogawa's proprietary software):

High-Speed, Multi-Channel Capability

The relationship between measurement intervals and the number of channels largely depends on the performance of the PC. The actual performance may differ from that shown in the table.

<PC System Requirements>
CPU: Pentium 4 3.2 GHz; Memory: 1 GB; OS: Windows 2000; Hard disk: 160 GB
Communication interface: Ethernet 100Base-TX

Multi-Interval Measurement

Three types of measurement intervals can be used in a single system in various combinations. Measurement intervals are specified for each module. It is also possible to set different types of input modules to the same measurement interval or to set the same type of input modules to different measurement intervals. Twelve measurement intervals are available as userselectable options: 10 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, 30 s and 60 s. Please note, however, that measurement intervals of 10/50 ms cannot be set to the Medium-speed Universal Input Module (MX110-UNV-M10).
   
Examples of Setting Measurement Intervals

Examples of Setting Measurement Intervals Multi-interval systems can be flexibly built for each module as shown in the figure below. Three colors Tm Mx100 04 are used to indicate the three types of measurement intervals.

Monitor Window Using Yokogawa's Proprietary PC Software

Monitor Window Using Yokogawa's Proprietary PC Software The window shows measurement values by measurement intervals. Measurement can be performed while confirming rapidly-changing signals and slowly-changing signals simultaneously.

A: Measurement of sine waves at 0.5 Hz with a measurement interval of 100 ms
B: Measurement of sine waves at 8 Hz with a measurement interval of 10 ms
C: Measurement of sine waves at 1 Hz with a measurement interval of 50 ms

High Withstand Voltage (Reinforced Insulation)

Reinforced (double) insulation has been provided between the input terminals and the case to achieve a high withstand voltage of 600 Vrms/VDC (continuous). As shown below, each battery voltage can be measured even if the batteries are stacked to increase common-mode voltages.

High Breakdown Voltage

Noise Rejection (MX110-UNV-H04)

MX input modules employ integrating A/D converters with superior noise rejection performance. In particular, the MX110-UNV-H04 Four-Channel High-Speed Universal Input Module incorporates an integrating A/D converter for each input channel, thereby exhibiting strong noise rejection performance in high-speed measurement. Moreover, the digital filtering function is effective on noises that cannot be fully rejected even with integrating A/D converters. Time constants can be selected from 5 to 100 measurement interval times. Therefore, filtering can be applied according to the noise to be rejected.

Example of Noise Rejection

When the noise source in the left figure was applied to the MX, the result in the right figure was obtained. High-speed measurement can be stably performed even in noisy environments.

Noise source applied to the MX
A noise signal was applied between
H and L (in normal mode).
Output window of MX100 for noise inputs
Module used: MX110-UNV-H04 Four-Channel High-Speed Universal Input Module

Measurement with the range of 2 V (-2 V to +2 V), measurement interval of 50 ms, integral time “Auto” and filter “OFF.”
Example of noise rejection
Example of Noise Rejection

System Configuration

Connection between a single MX unit and a single PC (measurement of 24 channels/10 ms or 60 channels/100 ms)

One MX unit enables data acquisition on up to 24 channels at a measurement interval of 10 ms, or up to 60 channels at a measurement interval of 100 ms (six modules installed in both cases).

 System Configuration Setting up the System
The MX and PC are connected via a hub and a straight Ethernet cable. Alternatively, they can be connected using a cross cable alone, without using the hub
 Input signal:
    DC voltageThermocuple,
    RTD,Digital input (Mixed input possible)
PC Software
In a one-to-one connection, the MX100 standard software included with the main module facilitates easy building of data acquisition environments.
One MX unit consists of a combination of a main module, input/output modules, and a base plate. This configuration centers on the main module.
 Output signal:
    Digital output

Connection between multiple MX units and a single PC

For measurement of up to 1,200 channels and the use of MXLOGGER

Example of a system with multiple MX units:

Example of a system with multiple MX units Setting up the System
The MX units and the PC are connected by means of a hub and straight Ethernet cables.

PC Software
Acquisition of data from multiple MX units is well-supported by Yokogawa’s software “MXLOGGER” (optional). MXLOGGER enables data acquisitions of up to 20 MX units (one unit has inputs of up to 60 channels, or 1,200 channels on 20 units).

Please note that the shortest measurement interval of MXLOGGER depends on the system's total number of channels and the PC's performance. For guidelines on measurement intervals and the number of channels, please visit….

If users wish to create their own data acquisition software, there is no limit to the number of MX units that can be integrated with a single PC software element. Please note, however, that if conditions with heavy loads (such as short measurement intervals with many units) are set to the PC and its software, data will not be acquired in time and some data may be lost.

Hardware Configuration

ModuleThe MX is designed to enable desired measurement environments by combining three elements: the main module, input/output modules, and a base plate.
The assembled unit can be utilized on the desktop as-is (the modules have legs). Please note that DIN rails are used for rack-mounting.
Hardware Configuration

Main Module (MX100)

The main module is the engine that controls data acquisition. It is equipped with a power supply, an Ethernet port, and a CompactFlash card slot. One main module can accommodate up to six input/output modules. The user can choose up to six moduels of any type.

Main Module (MX100)
Ethernet port:

For communication with the PC. Automatic recognition of 100Base-TX or 10Base-T

CF (CompactFlash) Card Slot:

CF
With the CF Card, measured data is saved to the card if communication with the PC is interrupted. Since the card provides data backup, you do not have to worry about the possible loss of data even if the MX is configured for PC-based measurement.

Data Backup Time by CF Card Size
(Note: Minutes/hours/days are approximate.)

Number of
saved channels
Measurement
interval
32 M 128 M 512 M
10 channels 10 ms 2 hours 9 hours 36 hours
100 ms 21 hours 3.5 days 15 days
500 ms 4.5 days 18.5 days 75.5 days
2 s 18 days 75.5 days 303 days
24 channels 10 ms 54 minutes 3.5 hours 15 hours
100 ms 9 hours 37 hours 6 days
500 ms 45 hours 7.5 days 31.5 days
2 s 7.5 days 31.5 days 126 days
60 channels 10 ms 18 minutes 75 minutes 5 hours
100 ms 3.5 hours 15 hours 2.5 days
500 ms 18 hours 3 days 12.5 days
2 s 3 days 12.5 days 50 days

Input Modules
 Input Modules

Name Model Number of channels Shortest measurement interval Description
30 ch general purpose input module with 500 ms scan speed MX110-VTDL30 30 500 ms Clamp terminal, DCV/TC/DI
MX110-VTDL30/H3 30 500 ms M3 screw terminal, DCV/TC/DI

MW100 input modules

Name Model Number of channels Shortest measurement interval Description
Universal Input Modules MX110-UNV-H04 4 10 ms DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
MX110-UNV-M10 10 100 ms DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
4-Wire RTD and Resistance Input Module MX110-V4R-M06 6 100 ms DC voltage, 4-wire RTD, 4-wire resistance, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.
Strain Input Modules MX112-B12-M04 4 100 ms Built-in bridge resistance of 120 ohm
MX112-B35-M04 Built-in bridge resistance of 350 ohm
MX112-NDI-M04 For connection with an external bridge head and strain gauge type sensor (NDIS connector))
5 V Digital Input Module MX115-D05-H10 10 10 ms Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed.
24 V Digital Input Module MX115-D24-H10 10 10 ms Level (24 V logic), Vth = 12 V


Output Modules

Name Model Number of channels Ouput update interval Description
Analog Output Module MX120-VAO-M08 8 100 ms Allows mixed voltage (±10 V) and current (4-20 mA) output
PWM Output Module MX120-PWM-M08 8 100 ms Pulse width modulation output module
Digital Output Module MX125-MKC-M10 10 100 ms “A” contact (SPST)

Base Plate

Base plates available for all configurations, from 1 to 6 input/output modules.

When used for the MW100/MX100, you must replace the attachment with the one that comes standard with the MW100/MX100.

Accessories

 Accessories Connector Covers
Connector covers for open slots

AC Adapter (772075)
AC adapter for the DC power model.
Operating temperature range: 0 to 40°
*Only for the MW100

Accessories (Removable Terminal)

N Mw100 10 All input/output terminals are removable except for those of the MX112-NDI-M04. If multiple terminals are prepared ahead of time, no re-wiring is needed between measurements.

 Accessories (Removable Terminal)
 

Resource & Download

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | Yokogawa- PC-BASED DATA ACQUISITION UNIT(Model: MX100).

Comments are closed.

02873000184

Model Description
772061 Screw (M4) terminal block (RJC (reference junction compensation) included).
For use in combination with 772062. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772062 Connection cable between input modules and the screw terminal block.
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772063 Plate with clamp terminals (RJC included).
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772064 Clamp terminals. Compatible with MX110-UNV-H04.
772065 Clamp terminals. Compatible with MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10.
772067 Plate with clamp terminals. Compatible with MX110-V4R-M06.
772068 Plate with clamp terminals (Built-in bridge resistance of 120 ohm). Compatible with MX112-Bxx-M04.
772069 Plate with clamp terminals (Built-in bridge resistance of 350 ohm). Compatible with MX112-Bxx-M04.
772080 Plate with screw (M3) terminal (RJC included).
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.
772081 Plate with clamp terminal for current with 10 ohm built in bridge resistance, applies to MX110-UNV-M10