HWg-PWR is a smart Ethernet gateway for remote energy metering and consumption monitoring. To measure the consumption of water, electricity and other energies, external meters with the M-Bus interface are used. Up to 3 / 12 / 25 M-Bus meters can be connected to the HWg-PWR unit. Individual meters (electricity meter, water meter, gas meter, heat meter etc.) are produced by third parties and connected via their M-Bus interface. HWg-PWR is a smart gateway that monitors energy consumption and warns about abnormal values The unit provides a Web interface, charts, SNMP and Modbus/TCP output, data logging, e-mail and SMS alerts, and much more.
Features
- Ethernet: RJ45 (100 Mbit)
- WEB: Built-in Web server, charts
- Data input: 3 / 12 / 25 external meters equipped with the M-Bus (EN 13757-2) interface
- M-Bus power: Meters powered from HWg-PWR
- M-Bus standards: EN 13757-2 (physical layer) & EN 13757-3 (application layer)
- Variables (data points): Up to 100 different variables from all (max. 25) meters
- M-Bus: Automatic detection of meters and available values
- Digital inputs: 8x Digital Input for 110/230V phase failure detection (senses tripped circuit breakers)
- Data logging: 170,000 values (3 values every 15 minutes = 590 days)
- Power: 110 or 230V AC
- Mechanical: Fits on a DIN rail
- M2M communication protocols: SNMP, XML, Modbus/TCP
- Response to thresholds: SNMP trap, E-mail, SMS (via SMS-GW)
- Portal: HWg-Push protocol, supports
- Graphs: Logging of values with the option to plot graphs
- Counter: Independent counter for periodic consumption readouts (daily, weekly, monthly, annually, …)
- Report: Periodic e-mailing of measured values
- SMS Gateway: Device can send SMS by external "HWg-SMS-GW" without any software.
- Support for programmers: HWg SDK
- Supported software
- HWg-PD Trigger: Control of other IP devices, alarm redirection to SMS
- HWg-PDMS: Logging, export to MS Excel
- >> Third-party SNMP software
(HP OpenView, IBM Tivoli, Nagios, Zabbix, Cacti, Monitor one, The Dude, Paessler IPCheck, Ipswitch WhatsUp, Axence nVision, CBR little:eye, LoriotPro, GFi NSM, SNMPc 7, CA NSM, ActiveXperts NM, Intellipool NM, MSC Operations Manager 2007)
- External M-Bus meters (third-party products)
- Values available over M-Bus depend on the meter – we recommend to always check the supported values with the manufacturer!
- Support for certified and calibrated meters
- Support for single-phase and polyphase electricity meters
- Support for single-tariff and multi-tariff meters
- Current transformers enable measurements of high currents
- Examples of typically available values:
- Instantaneous power input
- Total consumption
- Line voltage
- Line current
- Power factor (cos φ)
- Flow speed
Inputs | Power | Web | M2M outputs | |||||||
---|---|---|---|---|---|---|---|---|---|---|
M-Bus meters | M-Bus variables | Digital inputs | Modbus/TCP SNMP |
SMS GW | E-mail report | HWg-Push | ||||
HWg-PWR 3 | 3 | Max 100 | 8x 110/230VAC | 110/230VAC | ||||||
HWg-PWR 12 | 12 | Max 100 | 8x 110/230VAC | 110/230VAC | ||||||
HWg-PWR 25 | 25 | Max 100 | 8x 110/230VAC | 110/230VAC | * | |||||
HWg-PWR Old model – no longer in production |
3 | Max 30 | 3x Dry Contact | 230V | – | – | – |
M-Bus or S0 pulse counter
S0 is a legacy system of counting pulses that correspond to a certain amount of energy.
The M-Bus interface is the current standard for energy metering. Unlike pulse counting (S0), it works with absolute values (that can be used for customer billing). In addition, M-Bus provides more values, such as the immediate current and voltage, cos φ, and so on.
An S0 to M-Bus converter can be used to connect S0 devices:
- HWg-CS52: M-Bus and S0 pulse counter energy metering
- HWg-CS33: S0 pulse counter with SNMP & Modbus/TCP output
M-Bus meter manufacturers
Caution: We recommend to always check and test what values does the manufacturer guarantee at the M-Bus interface.
Gas meters |
Water meters |
Heat meters |
Electricity meters |
Other accessories |
|
---|---|---|---|---|---|
ABB | – | – | – | TESTED | – |
AllMess | – | – | – | ||
Aquametro | – | – | – | ||
Bmeters | – | – | – | – | |
Carlo Gavazzi | – | – | – | – | |
DEIF | – | – | – | TESTED | – |
DIEHL | – | – | TESTED | – | – |
EIZ – SCHRACK | – | – | – | TESTED | – |
Elster | – | – | – | – | |
Elvaco | – | – | – | TESTED | |
EMH | – | – | – | – | |
EMU | – | – | – | – | |
Günther Schell | – | – | – | – | TESTED |
GMC-I | – | – | – | – | |
GWF | TESTED | – | |||
IME | – | – | – | – | |
Inepro / DMMetering | – | – | – | – | |
ISKRAEMECO | – | – | – | – | |
ista | – | TESTED | – | – | |
Itron | – | ||||
Janitza electronics | – | – | – |
Resource & Download
Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | HWg-Smart M-Bus to Ethernet gateway (Model: HWg-PWR 3/12/25).
|
Comments are closed.