Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.
Overview:
The FGA 900 series of combustion efficiency monitors use dual sensor technology to measure the levels of up to Carbon Monoxide (CO) and Oxygen (O2) in a single compact unit.
Key Features
– Fully integrated system in a single compact box – no additional components required
– Suitable for a wide range of applications – up to 3 gases in a single analyzer
– Simple installation – locate the analyzer anywhere, including outside locations
Key Benefits
– Combustion efficiency measurement – for optimizing process efficiency where conditions are changing
– Low maintenance – straightforward servicing without specialist skills
– Proven high performance – dual sensor measurement technique, T�V and MCerts approved/Certified to US EPA standards
Specification:
Technical Details |
---|
Measurement Ranges | |
CO Ranges: | 0 – 50 ppm up to 0 – 2 000 ppm |
Resolution: | 1 ppm / 1 mg/m3 |
Linearity: | < 2 % of range |
Zero drift: | < 2 % of range per month |
Span drift: | < 2 % of range per month |
O2 Ranges: | 0 – 5 % to 0 – 25 % |
Resolution: | 0.1 Vol % |
Linearity: | < 0.2 Vol % |
Zero drift: | < 0.2 Vol % per month |
Span drift: | < 0.2 Vol % per month |
Calibration: | Microprocessor controlled |
Standard: | Manual gas selection |
Display: | LCD with backlight |
Indicators: | External 'Power On' and 'System OK' LEDs |
Outputs/Inputs | |
Analog outputs: | Isolated current loop outputs Efficiency (on FGA 930E only) 0, 2, or 4 to 10 or 20 mA |
Relay outputs: | System OK; Maintenance/Calibration |
Relay rating: | Isolated changeover S.P. 1 A @ 240 V a.c. 5 A @ 240 V d.c. resistive for Alarm – one per gas measured Span and Zero Gas Relays for calibration gases |
Inputs: | Current loop inputs for ambient and process temperatures (only needed for FGA 930 E) |
Environmental | |
Environmental rating: | IP65 / NEMA 4 |
Operating (ambient) temp.: | 0 to +35 °C / 32 to 95 °F standard to -20 °C / -4 °F with optional case heater to +50 °C / 122 °F with optional air conditioner |
Compliance |
|
Measurement standards: | Meets the requirements of ISO 12039, ISO 10849 and ISO 7935 |
Approvals: | MCerts for Continuous Emissions Monitoring Systems (Nov 1998) T�V approved to the 13th & 17th BImSchV and TA L�ft USEPA certified to PS-3, PS-4 and PS-4A |
Electrical safety: | Conforms to EN-61010-2 |
EMC: | Conforms to EN-50 081 & EN-50 082 |
Power | |
Power supply: | 110 V a.c. or 230 V a.c., ±20 %, 50 – 60 Hz |
Power consumption: | 300 W |
Gas and Air requirements | |
Instrument air (zero calibration): | 2 bar / 30 psi clean and dry, 5 l/min / 0.2 cfm |
Instrument air (cooling): | 2 – 10 bar / 30 – 150 psi clean and dry, 90 l/min / 3 cfm |
Calibration gas (recommended): | 2 bar / 30 psi, 5 l/min / 0.2 cfm 20 Liters / 0.7 cu.ft. per calibration approx. |
Calibration gas type: | Specific to each gas type and measurement span |
Dimensions (HxWxD): | 600 x 600 x 350 mm / 24 x 24 x 14 in |
Weight: | 53 kg / 117 lb |
Options | |
Special measurement ranges | |
Automatic calibration | |
Efficiency measurement (FGA 930 E only) | |
Probe type | |
Sample line type | |
Case heater | |
Air conditioner/vortex cooler |
Resource & Download
Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | Land-Extractive combustion analyzer ( Model: FGA 900 series).
Comments are closed.