Signal Recovery- Digital Signal Averager (Model: FASTFLIGHT-2)

215
1448
Vui lòng liên hệ với chúng tôi– chúng tôi sẽ liên hệ lại với khách hàng bằng điện thoại hoặc email.
Lưu ý: Tham khảo ý kiến của nhân viên INO sẽ giúp bạn tiết kiệm được thời gian và chi phí khi cần mua sắm. ​​Với sự tư vấn của chúng tôi, bạn sẽ không gặp khó khăn khi tìm hiểu về đặc tính của sản phẩm cần mua.

Overview

With its ability to process up to 100 averaged spectra per second, while responding proportionally to multiple ions in each detector pulse, the FASTFLIGHT-2 is a superior solution for data acquisition in LC/TOF-MS and GC/TOF-MS applications. Chromatograph technology is advancing towards shorter retention times, and this pushes the time-of-flight
mass spectrometer (TOF-MS) to acquire averaged spectra much more rapidly. FASTFLIGHT-2 improves the TOF spectra processing rate by a factor of 10 compared to first-generation digital signal averagers, thus enabling much faster chromatographs.

Because it employs a sampling ADC and a hardware digital signal averager, FASTFLIGHT-2 can handle the high ion rates encountered in LC/TOF-MS, GC/TOF-MS, Ion-Trap/TOF-MS and MALDI I TOF-MS without suffering the dead-time distortions inherent in a time-to-digital converter (TDC). Compared to transient digitizers and digital sampling oscilloscopes, which suffer from slow software averaging, FASTFLIGHT-2 delivers averaged spectra many orders of magnitude faster.

The innovative, automatic correlated noise subtraction feature means FASTFLIGHT-2 can also be a productive solution for the lower ion rates encountered in quadrupole/quadrupolefTOF mass spectrometers (QqTOF-MS), previously considered to be the exclusive domain of TDCs and time digitizers.

  • 250 ps interleaved and 500 ps real-time sampling intervals helps resolve the narrowest peaks
  • Sustained TOF-MS rates up to 100 averaged spectra/s (with negligible dead time) in the Chromatograph/TOF-MS mode for super-fast chromatographs
  • Simple cable connection to the USB-2 port on your PC no need to find scarce space inside your computer
  • Automatic data compression by factors up to 400:1 greatly reduces the chromatograph/TOF-MS file size
  • Automatic correlated noise suppression to <0.004% of full scale resolves a 25,000:1 concentration range
  • Rapid Protocol Port for changing acquisition modes with 10µs for multiplexed, multimode chromatographs

Specifications

Hardware 
PERFORMANCE
Amplitude Digitizing Resolution 8 bit- ADC nominally spans 500 mV at the Analog Input.
Precision Enhancer Extends the limiting ADC resolution to 12 bits (for input noise <2 mV) when circa 256 or more records are averaged3.  Optionally, on or off.
Differential and Integral Non-Linearity (DNL and  INL) Measured from 5% to 95% of full scale using a 500 mV, 70 µs ramp, with Precision Enhancer on.
  DNL within ±0.1 LDB referred to the 8-bit ADC.
  INL within ±0.4% of full scale. 
Analog input Bandwidth DC to 500 MHz; rise adn fall times <1 ns.
Equivalent input Noise (Measured with 500 ps sampling and 50 µs record lenght.)
  Uncorrelated with the Trigger <2 mV rms.
  Correlated with the Trigger <0.02 mV (typically 0.01
  mV rms) with Automatic Correlated Noise Substruction.
Automatic Correlated Noise Substruction Automatically assesses the correlated noise in each spectrum and substracts it without compromising data throughout rates.  Optionally, on or off.
Analog DC Offset (Vertical Offset) Zero offset of the ADC is computer adjustable from -250 mV to +250 mv with 0.03 mV resolution, referred to the Analog input.
Sampling intervals Hardware 500 ps, 1 ns or 2 ns real-time sampling with one scan per pound; 250 ps interleaved sampling with two scans per second4.
Software can display 250 ps interpolated sampling from a spectrum sampled at 500 ps.
Record Size (Hardware) 8 bits per sampled point and up to 1.5 M points per record (at 250, 500, 1000 ir 2000 ps/point.  Record length selectabel from a minumum of 10 µs to a maximum of 1.5 M points in steps of 512 points.
Spectrum Size (Hardware) Identical to Record Size, except 24 bits per sampled point, providing rapid hardware summing of up to 65,535 records ub a spectrum.
ADC Sampling
Interval (ps)
Min. Spectrum
Length (µs)
Max. Spectrum
Lenght (µs)

250

10

375

500

10

750

1000

10

1500

2000

10

3000

Data Acquisition Delay (Time Offset) Computer selectable digital delay after trigger from 0 to 1048.56 µs in 16-ns steps.  The record starts after the selected delay.
Dead Time End-of-Scan 0.8 µs.
End-of-Spectrum 0.8 µs.
Sampling Clock 2 GHz ±5 ppm; temperature sensitivity: within ±2.5 ppm, 0ºC to 50ºC.
Trigger-to-First-Sample Jitter Trigger Input within 500 ps (next clock pulse).
Trigger Output <50 ps FWHM.  (The Trigger Output is alternatively delayed by 0 and 250 ps relative to the sampling clock in the 250 ps interleaved sampling mode.)
Operating Temperature Range 0 to 50ºC
Averaging Method Linear summation of sequential records.
Selectable Stop-Acquisition Limits Maximum Time 1 second to 65,535 seconds ( 8 hr.), in 1-second steps, or disabled.
Max. Number of Spectra > 18,000.  Limited only by available memory in the supporting PC and the data storage disk.
Data Compression Implemented in the hardware with no compromise in data throughout. 
  Lossiess Compression down to 2/3 the normal 24-bit file size
  in spectra dominated by background, and with no loss of
  original data.
  Peak-Preserving and Background-Rejecting5
 
Automaticallly separates peaks from background.  Transmits
  peaks and adjacent background points.  Typically decimates
  98% of the background points between peak regions.  Data
  compression by a factor of 10 to 30, depending on peak
  density.
  Peak Centroid and Net Area Tranmits only the centroid and
  net area of automatically detected peaks.  Provides an
  additional factor of 9 data compression relative to Peak-
  Preserving and Background-Rejecting compression.
Maximum Data (Spectra) Transfer Rate Up to 100 spectra/s transferred to PC RAM and hard disk for a 50 µs spectrum length and 500 ps sampling in the Chromatograph/TOF-MS mode.
Total-ion/Specific-ion Chromatographs Automatic hardware computation of real-time Chromatograph displays with each point in the chromatograph linked to the supporting time-of-flight spectrum.  Provides exact time synchronization of the chromatograph with the TOP-MS when analyzing the output of an LC or GD.  The vertical chromatograph coodinates is:
  Total-ion Chromatograph The sum of the areas above
  background for all peaks in each spectrum. 
  Specific-ion Chromatograph The net area above background
  in the TOF-MS peak selected by the operator.  Optional pre- and
  post-acquisition selection.
Time Stamp 42 bits in the spectrum header are allocated to recording the starting time of each spectrum with 10 µs precision.  Maximum: circa 1.4 years.
Spectrum Number 21 bits in the spectrum header are allocated to recording the sequential spectrum number.  Maximum limit is circa 2 million. Reset to zero on each acquisition start.  Otherwise, this counter runs continuously, even when software stops reading the 32 MB FIFO output.
Output Buffering During the last record in each spectrum the sum of all records in the spectrum is written to a one-spectrum-deep output buffer, and the summing memory is released to acquire the next spectrum.  this limits end-of-spectrum dead time to 0.8 µs.  After data processing in the compressor, the spectrum is loaded into a 32 MB output FIFO memory to accommodate intermittent data transfer over the USB-2 bus to the PC without loss of spectra.  the output FIFO has a capacity of at least 7 spectra.
Rapid Protocol Selection Provides a hardware interface to change acquisition parameters in real time with 10 µs.  Includes 4 bits to select the hardware parameters defined in one of 16 products, and an additional 4 bits to insert one of 16 tags in the spectrum header.  The tags can be used to identify unique acquisition conditions from other parts of the mass spectometer.

Lưu ý: Nếu một thiết bị nào đó không được liệt kê ở đây, điều đó không có nghĩa rằng chúng tôi không hỗ trợ được bạn về thiết bị đó. Hãy liên hệ với chúng tôi để biết danh sách đầy đủ về thiết bị mà chúng tôi có thể hỗ trợ và cung cấp.
INO: Bán, Báo giá, tư vấn mua sắm và cung cấp, tư vấn sản phẩm thay thế; tương đương, hướng dẫn sử dụng, giá…VNĐ, …USD info@ino.com.vn | 02873000184 | Signal Recovery- Digital Signal Averager (Model: FASTFLIGHT-2).

Comments are closed.