AOIP-ACQUISITION SYSTEM-Hệ thống thu nhận và truyền dữ liệu

169
1084

Display and keyboard multichannel datalogger: SA32

This stand alone acquisition system is a versatile system: From 8 input channels in RTD and resistance to 16 channels in voltage, current and thermocouples.

Programming can be performed either with the keyboard and display or using the standard RS232 or RS485 connection so the user can download data and program the instrument.

The internal memory allows measurements from the analogue inputs and calculations to be stored, as well as the processing of channel results.

Due to its high accuracy level (up to 0.01% reading), this instrument is the perfect tool for temperature sensor calibration and monitoring of critical temperature applications.

This stand alone acquisition system is a versatile system: From 8 input channels in RTD and  resistance to 16 channels in voltage, current and thermocouples. Programming can be performed either with the keyboard and display or using the standard RS232  or RS485 connection so the user can download data and program the instrument. The internal memory allows measurements from the analogue inputs and calculations to be stored,  as well as the processing of channel results. Due to its high accuracy level (up to 0.01% reading), this instrument is the perfect tool for  temperature sensor calibration and monitoring of critical temperature applications.

Modular multichannel dataloggers: DATALOG SERIES

These systems consist in a modular base station completed with input/output boards. Users can select the perfect custom-built system in accordance to its needs while it remains upgradable for future applications.

2 models cover the needs for applications from 1 to 300 channels.

Display and keyboard allow onsite programming. 

Calculation channels allow data to be processed and monitored online: statistics, channels corrections and calculations. 

With 0.008 % accuracy covering all RTDs and thermocouples, it is the perfect instrument for monitoring applications involving a large number of channels, as well as for pharmaceutical 

validations.

The system is 21 CFR Part 11 compliant and makes a complete traceable instrument for sensitive and sharp applications when used together with VISULOG software.

This set of instruments is made after user requirements. It is based on a data acquisition system equipped with one or more standard probes, a temperature source and VISULOG software with the optional calibration module. It can calibrate several temperature sensors at the same time, set calibration setpoints, stability  and homogeneity conditions.  A report is printed with calibration results while calibration data can be stored on a computer.  Polynomial corrections are calculated and suggested to users for specific applications. Several calibration procedures can be defined and run manually or completely automatically.

Temperature sensor calibration solutions

This set of instruments is made after user requirements.
It is based on a data acquisition system equipped with one or more standard probes, a temperature source and VISULOG software with the optional calibration module.
It can calibrate several temperature sensors at the same time, set calibration setpoints, stability and homogeneity conditions. 
A report is printed with calibration results while calibration data can be stored on a computer. 
Polynomial corrections are calculated and suggested to users for specific applications.
Several calibration procedures can be defined and run manually or completely automatically.
Typical Application example
Mapping of thermal and climatic chambers: either in food and drug laboratories, high tech industries or health centers, thermal chambers, incubators, fridges have 
to be calibrated performing mapping in order to control their behaviours.

Comments are closed.